woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/iftihcom/public_html/scientific/wp-includes/functions.php on line 6131genesis domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/iftihcom/public_html/scientific/wp-includes/functions.php on line 6131hello_pro domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/iftihcom/public_html/scientific/wp-includes/functions.php on line 6131When cost is a primary consideration of selection, the Series 1000 provides low cost, high specification, quality instruments for both the UV and visible ranges.
The designs offer an ideal combination of performance, quality and reliability for educational use; as is witnessed by the large number of Universities, Polytechnics and Colleges who are multiple users of the range.
With only six, carefully programmed operating keys, the Series 1000 spectrophotometers are exceptionally easy to use. Up-
Very precise wavelength selection, with readout to 0.1nm, provide the high degree of reproducibility needed for accuracy, particularly when measuring on a sloping background.
UV-
Design advantages of the series 1000 instruments include self test and calibration at switch on, automatic lamp and filter selection coupled to wavelength and high overall stability eliminating frequent resetting of the Absorbance zero when making extended measurements.
Peak Seek
The measurement of an absorption band should always be carried out at the wavelength of peak absorption to obtain results of the highest accuracy and reproducibility.
An automatic peak seek facility is provided. To enhance discrimination and accuracy automatic compensation of the reference energy background –
Sample Temperature Control
Temperature control by water circulation is possible with the Series 1000 for a single cell, SIP flowcell, or for 4 cells mounted on the cell changer. A special sample compartment lid and pipe port are provided for use with water temperature control.
Used with Series 1000 instruments the SIP sampling accessory allows samples to be measured without the inconvenience of cell handling, or danger of cell breakage. Samples are drawn into the cell by depressing the sample key on the control panel, to displace the previous sample.
The pump unit is mounted within the cell compartment. Cells of up to 40mm pathlength are available and samples as small as 300µl may be measured in a 10mm pathlength cell.
The large and accessible sample compartment accommodates a wide range of sample holders in addition to the standard single cell holder. These include a 4 cell changer, water thermostatted cell holders and a SIP sampling system which fits within the sample compartment.
]]>