High Performance Liquid Chromatography (HPLC)

LOW PRESSURE GRADENT MIXING

Q–ADEPT HPLC SYSTEM Q-2, Binary – Low Pressure Gradient

This is a low pressure binary gradient forming system. It uses the CE 4102 dual piston pump with flow rates from 0.001 to 10mL/min and a maximum operating pressure of 40MPa.

The pump has the facility for mixing two solvents for binary gradients and of course may be used in the isocratic mode.The Adept CE 4200 dual wavelength detector is used with an 8µL x 10mm flowcell. The Rheodyne valve fitted with a 20µL loop is mounted with the column on the mounting panel CE 4050.The PowerStream software controller is mounted at the centre of the stack. Full control and data processing are provided for use with Windows.

A Solvent Reservoir and Pipe Organizer and installation kit are also supplied.


Q-ADEPT HPLC SYSTEM Q-4, Quaternary – Low Pressure Gradient

This extremely popular quaternary low pressure gradient system is shown here with a Cecil column heater/chiller, which should be ordered extra if required. The CE 4104 dual piston pump has flow rates from 0.001 to 10µL/min and a maximum operating pressure of 40MPa. The pump has all the facilities for gradient formation, with low pressure mixing of up to 4 solvents.

Four, proprietary, high performance, high reliability, proportioning valves are used to control up to four solvents and a high performance, low volume, dynamic mixer is used for ultimate gradient quality.

The Adept CE 4200 dual wavelength detector is used with an 8µL x 10mm flowcell. The Rheodyne valve with 20µL loop is mounted by a small panel to the detector. When an oven is not used the column may be mounted together with the valve on mounting panel CE 4050.

The CE 4900 Power Stream system controller is placed at the center of the very compact stack. Full control and data processing are provided for use in Windows. The system is supplied complete with solvent and pipe organizer, CE 4134, 8µL x 10mm flow cell and installation kit 4150 14 00.


Q-ADEPT HPLC SYSTEM Q-4S, Method Development

This is the ideal system for sophisticated method development. The system offers power and flexibility and yet is compact and convenient to use.

The CE 4104 Quaternary pump is provided for low pressure mixing of up to 4 solvents. A dynamic mixer, built into the pump, provides excellent solvent mixing for reproducible gradients.

The Adept CE 4300 WaveQuest DAD fast scanning detector is supplied with an 8µL x 10mm flowcell and fitted with a mounting panel for the Rheodyne injection valve.

Purity, compound identification, match factors using library search and virtually drift free monitoring may be carried out using this excellent system on the same scan as peaks are quantified cutting experimental time in half.

The PowerStream system controller is mounted at the centre of the stack and full control and data Processing are provided for use in Windows. A solvent and pipe organiser, CE 4134 and installation kit 4150 14 00 are provided.

The system is completed by the CE 4600 heated and cooled oven, which accommodates up to three columns.


HIGH PRESSURE GRADIENT MIXING

ADEPT HPLC SYSTEM 1, Analytical Isocratic

This simple system is ideal for routine isocratic separations and quality assurance applications. High sensitivity is provided by the Adept CE 4201 UV-Visible variable wavelength detector with 8µL x 10mm flowcell. Precise delivery of the mobile phase is provided by the Adept CE 4100 dual piston high pressure solvent delivery pump which delivers flow rates from 0.001 to 10mL/min with a maximum operating pressure of 40MPa. The pump head is constructed with ceramic inserts to provide bio- compatibility.

The system may be upgraded to provide data processing and is supplied with column mounting panel and cover and Rheodyne injection valve with a 20µL loop, solvent and pipe organiser CE 4033, 8µL x 10mm flowcell and installation kit 4150 01 00.


ADEPT HPLC SYSTEM 2, Analytical Isocratic with Data Processing

This system uses the Adept CE 4100 dual piston pump and the Adept CE 4200 dual wavelength detector for added flexibility and is provided with PowerStream data processing software and interface unit, CE 4901.

PowerStream software, CE 4901, operates in Windows. It offers the same data processing power as the CE 4900 software but unlike the latter, offers no system control. The system is supplied complete with column and valve mounting panel, Rheodyne injection valve with 10µL loop, solvent and pipe organiser CE 4033, 8µL x 10mm cell and installation kit 4150 01 00.


ADEPT HPLC SYSTEM 3, Automatic Analytical Isocratic

Routine analysis of large numbers of samples may be carried out using this system which requires minimum operator attention. System control and data processing are provided by PowerStream software and interface CE 4900. The elegant, powerful and very easy to use software operates in Windows.

A range of autosamplers accommodates large numbers of samples. The system, like all the Adept systems, uses the CE 4100 dual piston pump with delivery speeds from 0.001 to 10mL/min.

The CE 4200 dual wavelength detector has a very low noise level, less than ± 0.35 x 10-5A peak to peak and incredibly low drift ± 3 x 10-5A/h at temperature equilibrium. The 8µL x 10mm flow cell, column panel and cover, solvent and pipe organizer CE 4033 and installation kit 4150 01 01 are provided.


ADEPT HPLC SYSTEM 4, Binary Gradient – High Pressure Gradient

Two Adept CE 4100 dual piston pumps, with flow rates from 0.001 to 10mL/min and a maximum operating pressure of 40MPa, are used with the dynamic mixer CE 4120.

The Adept dual wavelength UV-Visible detector CE 4200 is used with an 8µL x 10mm flow cell. A column mounting panel, cover and Rheodyne valve with a 20µL loop are provided.

The software provides full system control and data processing using Windows. The system is supplied with solvent and pipe organizer CE 4033 and installation kit.

 

 


HPLC Pump CE 4100
HPLC Pump CE 4100
Flow Rate 0.001 to 10mL/min in 0.001 steps
Flow Reproducibility Better than 0.1%
Maximum Pressure 40MPa = 400 bar
User Interface 4 line back-lit display

Full range of keys for menu and parameter selection

Fast number entry keys

Over Pressure Cut-out Adjustable between 3 and 40MPa
Low Pressure Cut-out Adjustable between 0 and 40MPa
Material in contact with fluids Ceramic inserts – biocompatible

Check valves – ruby and sapphire

Pulsation Less than ±0.5% at 2mL/min
Size and Weight 365 x 290 x 140mm, 7.5kg
Power Requirements 115V or 230V, 50/60Hz, 30VA

 

 


Quaternary Low Pressure Pump CE 4104
Quaternary Low Pressure Pump CE 4104
Flow Rate 0.001 to 10mL/min in 0.001/min increments
Pressure Range 0-40MPa over flow range
Flow Accuracy <±0.5%
Flow Precision <0.1% RSD
Pressure Pulsation <±0.5% at 2mL/min
Gradient Forming Quaternary to Binary low pressure mixing and isocratic high pressure operation
Gradient Control Using proprietary high-speed proportioning valves
Gradient Precision Typically 0.2% RSD at 1mL/min
Material in contact with fluids Ceramic inserts, ruby and sapphire check valves, PEEK
Gradient Forming Binary gradient low pressure mixing and isocratic high pressure operation

 

 


Dual Wavelength, Programmable UV Visible Detector CE 4200
Dual Wavelength, Programmable UV Visible Detector CE 4200
Noise ±0.35 x 10-5 A at 230nm, 2s, using air test cell
Drift ±0.3 x 10-4 A at 230nm, 2s, using air test cell
Dual Wavelength Operation Simultaneous measurements at 2 wavelengths

Output of Absorbance ratio for the 2 wavelengths

Noise, Dual Wavelength ± 2 x 10-5 A peak to peak 230/280nm 1s time constant
Drift, Dual Wavelength ± 1 x 10-4 A/hour at constant temperature
Programmed Operation Programs may be entered to change parameters, operating modes and select up to 6 different wavelengths in any time sequence.

 

 


UV-Visible Detector CE 4201
UV-Visible Detector CE 4201
Optical System Double beam with 1200 lines/mm grating monochromator
Wavelength Range 190-700nm
Wavelength Accuracy ± 1nm
Wavelength Precision ± 0.1nm, single wavelength mode
Optical Bandwidth 8nm
Straylight < .02%, 220nm
Lamp Deuterium lamp with elapsed time indicator
Absorbance Range 0.001 to 2A full scale in 11 ranges
Time Constant 0.1, 0.2, 0.5, 1, 2, 5 and 10 seconds
Display Four-line display of parameters, menus, prompts, wavelength, Absorbance etc.
Fast Number Entry By use of special number keys
Event Marking From keypad or by external source
Method Storage For up to 30 methods, security protected
Second Order Filter Fast automatic insertion at 370nm
Noise ± 1 x 10-5 A peak to peak, 220nm, 2s time constant
Drift ± 1 x 10-4 A/hour at constant temperature
Linearity Better than 1%, 0.001 – 2A
Automatic Power-up/off Pre-programmed from keypad to save warm up time
Sample Flow Cell 8µL x 10mm pathlength – normal

4µL x 5mm pathlength

Wetted surfaces PEEK, Teflon and Fused Silica

Other cells available

Refractive Index Sensitivity < ± 5 x 10-4 A, water to methanol at 350nm
Flow Rate Sensitivity < ± 3.5 x 10-3 A, for flow change 1-2mL/min, 300nm
Outputs Two Absorbance outputs and Absorbance ratio to recorder. All data available to PowerStream System Manager.

 

 


WaveQuest D.A.D. Ultra Fast Scanning Detector  CE 4300
WaveQuest D.A.D. Ultra Fast Scanning Detector  CE 4300
Optical System Double beam
Monochromator With 1200 l/mm holographic grating
Wavelength Range 190-700nm
Optical Bandwidth 4nm – constant
Digital Resolution 1nm
Wavelength Accuracy 1nm
Wavelength Reproducibility 0.1nm
Absorbance Range 0 to 3A
Scan Speeds Up to 1000nm/s
Baseline Flatness ± 0.002A over most of range
Straylight <0.02% at 220nm and 340nm
Noise < ±0.5 x 10–5 A at 230nm, 2s air test cell
Drift < ±0.5 x 10–4 A at 230nm, using air test cell
Calibration and Test Automatic at switch-on
Display Four line display of parameters, menus, prompts, wavelength, Absorbance etc.
Number of Peak Scans Up to 100 peaks for any single elution
Multiple Scans of a Peak Up to 8 scans of any peak
Scan Trigger At start, set Absorbance value, point of inflection or at maximum
Scan Storage Up to 100, password protected, unlimited with PowerStream
Method Storage Up to 30 methods, password protected
Size 365 x 290 x 140mm, 17Kg
Power Requirement 115V or 250V, 50/60Hz, 50VA

 

 


Refractive Index Detector CE 4700
Refractive Index Detector CE 4700
Measuring Ranges ± 10-4 RIU
Sensitivity 8 x 10-8 RIU
Noise 8 x 10-8 RIU
Time constants 0.1, 0.2, 0.5, 1, 2, 5, 10 seconds
Cell volume 9µL
Outputs -1V to +1V, 20 bit resolution
Size and weight 360 x 140 x 260mm, 9.5kg
Power requirements 100-250V, 50/60Hz, 6VA

 

 


Fluorescence Detector Dual Monochromator CE 4500
Fluorescence Detector Dual Monochromator CE 4500
Light Source 10W Xenon flash lamp, frequency programmable
Detector Photomultiplier
Excitation Monochromator 200-650nm
Emission Monochromator 200-900nm, with extended range photomultiplier
Wavelength Scanning Excitation and emission independently programmable
Sensitivity S/N >3000 for 4µg/L Anthracene in Methanol
Analogue Outputs 10mV, 100mV and 1V
Power Requirements 100/240V, 50/60Hz

 

 


Conductivity Detector CE 4710
Conductivity Detector CE 4710
Conductance Display Range 0.01 – 5000µS. cm-1
Time Constant 0.1, 0.2, 0.5, 1, 1.5, 2, 5s
Autozero Range Typically up to 10,000µS. cm-1
Synchronous Detection Frequency 5KHz
Noise Less than ±1nS/cm, DI water, 1mL/min, 2s
Drift Less than ±10nS/cm/h, DI water, 1mL/min,
Cell Volume 0.5µL
Cell Body PEEK P1000 grade
Electrodes 316 stainless steel
Cell Pressure Rating 200psi
Operating Temperature 25 – 50ºC; 35ºC standard
Temperature Precision ± 0.01ºC
Warm-up Time 10 minutes typical
Method Storage Up to 100 with password protection
Outputs 0-1V analogue and RS232
Digital Control By PowerStream software

 

 


Electrochemical Detector CE 4720
Electrochemical Detector CE 4720
Working electrode Glassy carbon (optional solid Ag, Au, Cu, Ni, Pt electrodes)
Auxiliary electrode Stainless steel
Reference electrode Silver/silver chloride salt bridge electrode or embedded silver electrode
Cell volume 120 nl with 50 µm spacer
Time Constant 0.1, 0.2, 0.5, 1, 1.5, 2, 5s
Noise Less than ±0.3 pA
Drift Less than 0.3 pA
Cell Pressure Rating 200 psi
Cell Enclosure Heater 20 watt
Operating Temperature 25 – 50ºC; 35ºC standard
Temperature Precision ± 0.01ºC
Warm-up Time 10 minutes typical
LCD Screen 4 lines, back lit, adjustable contrast
Method Storage Up to 100 with password protection
Analogue Output 0-1V
Remote Autozero By contact closure
Keypad Control For entry of values, commands and Programmes
Working potential ±2.5 V
Measuring range ±10 pA to 5 mA
Size & Weight 365 x 290 x 140 mm, 7.5kg
Power Requirements 115V or 230V, 50/60Hz, 40 Watt